NANDAKUMAR.P.R
MECHANICAL ENGINEER
NEAR RAMADA,DOHA-QATAR
MOB: 33591634 , nandakumar.pettikkattil@gmail.com
(Transferable ...
 Fabrication and Erection of 64”- 32”, 24”- 12”, 10”- 6” concentric reducer
 10” pipe 500M Butt welding
 24” Flange wel...
Nandakumar-Mechanical Engineer
of 3

Nandakumar-Mechanical Engineer

Published on: Mar 3, 2016
Source: www.slideshare.net


Transcripts - Nandakumar-Mechanical Engineer

  • 1. NANDAKUMAR.P.R MECHANICAL ENGINEER NEAR RAMADA,DOHA-QATAR MOB: 33591634 , nandakumar.pettikkattil@gmail.com (Transferable visa / NOC Available) PASSPORTNO:M0762247 DATE OF ISSUE: 08/08/2014, DATE OF EXPIRY: 07/08/2024 OBJECTIVE & SKILLS Mechanical engineering under graduate with more than 2.5 years’ experience in multilevel engineering and analysis works at petroleum refinery with strong will and passion, seeking a challenging position at your esteemed organization, to exploit and execute the inherent skills while maintaining continuous learning, to ensure the steady organizational as well as personal growth  Excellent communication and management skillsaiding Workflow, Complaint resolution and Employee relations  Professional and academic experience in Mechanical Drafting Software including AutoCAD, Solidworks  Highly fluent in general computer skillsincluding Microsoft office suite EDUCATION & CERTIFICATIONS  Bachelor of Engineering (Mechanical) - Annauniversity, Kavery college of engineering and technology, Chennai, India (01/2008 - 05/2012)  STCW(PSSR,PST,EFA,FPFF,HUET), SETRAC, Mumbai  QA/QC in N.D.T Piping & Welding, N.D.T Level II in Penetrant Testing, Visual Testing, Ultrasonic testing, Magnetic testing, Radiographictesting, RadiographicFilm Interpretation fromQualimation, Kochi, Kerala, India  Six Sigma Green Belt Certificate from Qualimation, Kochi, Kerala, India  BIM-Building information Modelling (MEP)  Revit-Autodesk Software  Navis Works EXPERIENCE SUPERVISOR - BPCL Cochin Refinery (Contractor– P.K.S Construction Ltd) (06/2014 – 10/2014) Integrated Refinery Expansion Project (IREP)  Supervised Cooling tower pipeline procedures including:  Fabrication and Erection of 84”, 74”, 64”, 24”, 12”, 10”, 6” Mitre  Fabrication and Erection of 84”- 64”, 74”- 54” eccentric reducer
  • 2.  Fabrication and Erection of 64”- 32”, 24”- 12”, 10”- 6” concentric reducer  10” pipe 500M Butt welding  24” Flange welding  54” Foot flange erection in cooling tower sump  Fabrication and Erection of grid platform  Hydro-testing and Coir Rolling in Cochin port including:  Site Management  Hydro-testing and Coir rolling of 10”, 8”, 4” thermoplastic hose (FO)  Hydro-testing and Coir rolling of 10”, 8”, 4”,rubber hose (SKO, MS, HSD, N) SUPERVISOR - BPCL Cochin Refinery (Contractor – P.K.S Construction Ltd) (05/2014 – 06/2014) FCCU shutdown  Supervision in Blinding and De-Blinding, Man-Way opening  Refractory chipping  Jaguar welding, Mesh welding, Resco applying  Maintenance in orifice chamber  Maintenance in regenerator SUPERVISOR - BPCL Cochin Refinery (Contractor – P.K.S Construction Ltd) (11/2012 – 1/2013) DHDS shutdown  Supervision in Blinding and De-blinding  Fabrication and erection of 2” hydrogen pipeline in HDU to DHDS  Supervised maintenance of heater including:  Full man-way opening, Side cover opening.  Burner maintenance, Maintenance in air chamber.  Refractory maintenance.  Maintenance in spring supports, shoe supports.  Maintenance in Swing elbow.  Hydro testing and shot blasting in radiant coil inside the heater.  Maintenance in convection coil.  Sight glass replacing.  Maintenance in thermo couples.  Maintenance in anchor supports on radiant coil.  Supervision in painting DECLARATION I hereby declare that all the information provided above is true and correct to my best of knowledge and belief Nandakumar.P.R Place : Date :

Related Documents