Local Solutions For Individual Customers Worldwide
Product Catalogue
Pressure Transmitter and Reader
of the PT-RF Series
L...
Local Solutions For Individual Customers Worldwide
Product Catalogue
Pressure Transmitter and Reader
of the PT-RF Series
L...
www.stauff.com www.stauff.com
Pressure Transmitter § Type PT-RF
Product Description
The pressure transmitters from the PT...
www.stauff.com www.stauff.com
Pressure Transmitter § Type PT-RF
Product Description
The pressure transmitters from the PT...
www.stauff.com www.stauff.com
Pressure Transmitter § Type PT-RF
Product Description
The pressure transmitters from the PT...
Local Solutions For Individual Customers Worldwide
Product Catalogue
Pressure Transmitter and Reader
of the PT-RF Series
L...
of 6

Pressure Transmitter and Reader of the PT-RF Series

Published on: Mar 4, 2016
Source: www.slideshare.net


Transcripts - Pressure Transmitter and Reader of the PT-RF Series

  • 1. Local Solutions For Individual Customers Worldwide Product Catalogue Pressure Transmitter and Reader of the PT-RF Series Local Solutions For Individual Customers Worldwide Product Catalogue PT-RF § English § 9910000263 § 04/2015 www.facebook.com/stauffgroup www.twitter.com/stauffgroup www.youtube.com/stauffgroup www.stauff.com Series PT-RF Pressure Transmitter and Reader of the Series PT-RF The PT-RF series of pressure transmitters are an alternative solution for universal pressure measurements for fluid technology applications, which will provide benefits for system operators, maintenance personnel and repair technicians as well as for original equipment manufacturers. The advantages resulting from the use of the new technology for system operators, maintenance personnel and repair technicians are clear: Measurements can be carried very easily, without extensive training and within a few seconds at the press of a button and then documented in a reliable process. Unscrewing and re-installing pressure gauges or other measuring and display devices – practically a temporary opening of the system – is not required. Potential hazards for people, machines and the environment, for example from emitted residual oil in the test hose or leaks at the measuring point, as well as ingress of dirt into the system (e.g. in dusty environments) can be effectively excluded. Original equipment manufacturers will also benefit from this new technology: If the pressure transmitters are installed at their factory already, the innovative technology can provide a competitive edge over alternative suppliers and open up specific advantages for the users, increasing the value retention of their own devices in the long term. If the pressure transmitters are installed directly in the system or pipeline for permanent use, they protrude only slightly more than conventional hydraulic test couplings and meet the highest demands with regard to space requirements and weight. www.stauff.com Originating and located in Werdohl in the German Sauerland region, we have become an internationally leading developer, manufacturer and supplier of pipework equipment and hydraulic components under the brand name STAUFF. The STAUFF product range includes: § STAUFF Clamps § STAUFF Test § Filtration Technology § Diagtronics § Hydraulic Accessories § Valves § Fluid Connectors Decades of experience, highly-motivated and qualified staff, state-of-the-art manufacturing technologies and a foresighted management give us the reputation of being a competitive partner. Our in-house laboratories carry out constant tests in line with international standards on all products. Certified in accordance with ISO 9001:2008 (Quality), ISO 14001:2004 (Environmental Protection) and OHSAS 18001:2007 (Occupational Health and Safety), our management system continually strives for perfection. Many of our products have been successfully tested and approved by several international organisations and institutes. Our well-stocked warehouses and flexible production lines ensure prompt reactions and short delivery times. Represented by a tight network of distributors and wholly- owned manufacturing facilities, distribution bases and warehouses in 18 countries worldwide, we are close to you. Our subsidiaries also supply additional retail products related to the fluid power industry, thereby offering a near-complete range of industry-specific key products. Local Solutions For Individual Customers Worldwide. GERMANY Walter Stauffenberg GmbH & Co. KG Im Ehrenfeld 4 58791 Werdohl Tel.: +49 23 92 916 0 Fax: +49 23 92 916 160 sales@stauff.com AUSTRALIA STAUFF Corporation Pty Ltd Tel.: +61 2 4271 9000 sales@stauff.com.au BRAZIL STAUFF Brasil Ltda. Tel.: +55 11 47 72 72 00 stauff@stauffbrasil.com CANADA STAUFF Canada Ltd. Tel.: +1 416 282 46 08 sales@stauffcanada.com CHINA STAUFF China Tel.: +86 21 68 18 70 00 info@stauff.com.cn FRANCE STAUFF S.A.S. Tel.: +33 2 54 50 55 50 direction@stauffsa.com INDIA STAUFF India Pvt. Ltd. Tel.: +91 20 66 20 24 66 sales@stauffindia.com IRELAND STAUFF Ireland Tel.: +44 28 92 60 69 00 sales@stauffireland.com ITALY STAUFF Italia S.r.l. Tel.: +39 031 65 84 94 sales@stauff.it KOREA STAUFF Korea Ltd. Tel.: +82 51 266 66 66 info@stauff.co.kr MALAYSIA STAUFF South East Asia Sdn Bhd Tel.: +60 3 5637 78 88 sales@stauff.com.my NEW ZEALAND STAUFF Corporation (NZ) Ltd. Tel.: +64 9 271 48 12 info@stauff.co.nz POLAND STAUFF Polska Sp. z o.o. Tel.: +48 58 660 11 60 sales@stauff.pl RUSSIAN FEDERATION STAUFF LLC Tel.: +7 495 276 16 50 sales@stauff.ru THAILAND STAUFF (Thailand) Co., Ltd. Tel.: +66 2 721 73 23 sales@stauff.co.th UNITED KINGDOM STAUFF UK Ltd. Tel.: +44 114 251 85 18 sales@stauff.co.uk UNITED STATES STAUFF Corporation Tel.: +1 201 444 78 00 sales@stauffusa.com VIETNAM STAUFF Vietnam Ltd. Tel.: +84 8 3948 10 41 sales@stauff.com.vn Globally available through wholly-owned branches and distributors in all industrial countries. Produktkatalog_PT-RF_EN_04-2015.indd 1 28.04.2015 10:16:13
  • 2. Local Solutions For Individual Customers Worldwide Product Catalogue Pressure Transmitter and Reader of the PT-RF Series Local Solutions For Individual Customers Worldwide Product Catalogue PT-RF § English § 9910000263 § 04/2015 www.facebook.com/stauffgroup www.twitter.com/stauffgroup www.youtube.com/stauffgroup www.stauff.com Series PT-RF Pressure Transmitter and Reader of the Series PT-RF The PT-RF series of pressure transmitters are an alternative solution for universal pressure measurements for fluid technology applications, which will provide benefits for system operators, maintenance personnel and repair technicians as well as for original equipment manufacturers. The advantages resulting from the use of the new technology for system operators, maintenance personnel and repair technicians are clear: Measurements can be carried very easily, without extensive training and within a few seconds at the press of a button and then documented in a reliable process. Unscrewing and re-installing pressure gauges or other measuring and display devices – practically a temporary opening of the system – is not required. Potential hazards for people, machines and the environment, for example from emitted residual oil in the test hose or leaks at the measuring point, as well as ingress of dirt into the system (e.g. in dusty environments) can be effectively excluded. Original equipment manufacturers will also benefit from this new technology: If the pressure transmitters are installed at their factory already, the innovative technology can provide a competitive edge over alternative suppliers and open up specific advantages for the users, increasing the value retention of their own devices in the long term. If the pressure transmitters are installed directly in the system or pipeline for permanent use, they protrude only slightly more than conventional hydraulic test couplings and meet the highest demands with regard to space requirements and weight. www.stauff.com Originating and located in Werdohl in the German Sauerland region, we have become an internationally leading developer, manufacturer and supplier of pipework equipment and hydraulic components under the brand name STAUFF. The STAUFF product range includes: § STAUFF Clamps § STAUFF Test § Filtration Technology § Diagtronics § Hydraulic Accessories § Valves § Fluid Connectors Decades of experience, highly-motivated and qualified staff, state-of-the-art manufacturing technologies and a foresighted management give us the reputation of being a competitive partner. Our in-house laboratories carry out constant tests in line with international standards on all products. Certified in accordance with ISO 9001:2008 (Quality), ISO 14001:2004 (Environmental Protection) and OHSAS 18001:2007 (Occupational Health and Safety), our management system continually strives for perfection. Many of our products have been successfully tested and approved by several international organisations and institutes. Our well-stocked warehouses and flexible production lines ensure prompt reactions and short delivery times. Represented by a tight network of distributors and wholly- owned manufacturing facilities, distribution bases and warehouses in 18 countries worldwide, we are close to you. Our subsidiaries also supply additional retail products related to the fluid power industry, thereby offering a near-complete range of industry-specific key products. Local Solutions For Individual Customers Worldwide. GERMANY Walter Stauffenberg GmbH & Co. KG Im Ehrenfeld 4 58791 Werdohl Tel.: +49 23 92 916 0 Fax: +49 23 92 916 160 sales@stauff.com AUSTRALIA STAUFF Corporation Pty Ltd Tel.: +61 2 4271 9000 sales@stauff.com.au BRAZIL STAUFF Brasil Ltda. Tel.: +55 11 47 72 72 00 stauff@stauffbrasil.com CANADA STAUFF Canada Ltd. Tel.: +1 416 282 46 08 sales@stauffcanada.com CHINA STAUFF China Tel.: +86 21 68 18 70 00 info@stauff.com.cn FRANCE STAUFF S.A.S. Tel.: +33 2 54 50 55 50 direction@stauffsa.com INDIA STAUFF India Pvt. Ltd. Tel.: +91 20 66 20 24 66 sales@stauffindia.com IRELAND STAUFF Ireland Tel.: +44 28 92 60 69 00 sales@stauffireland.com ITALY STAUFF Italia S.r.l. Tel.: +39 031 65 84 94 sales@stauff.it KOREA STAUFF Korea Ltd. Tel.: +82 51 266 66 66 info@stauff.co.kr MALAYSIA STAUFF South East Asia Sdn Bhd Tel.: +60 3 5637 78 88 sales@stauff.com.my NEW ZEALAND STAUFF Corporation (NZ) Ltd. Tel.: +64 9 271 48 12 info@stauff.co.nz POLAND STAUFF Polska Sp. z o.o. Tel.: +48 58 660 11 60 sales@stauff.pl RUSSIAN FEDERATION STAUFF LLC Tel.: +7 495 276 16 50 sales@stauff.ru THAILAND STAUFF (Thailand) Co., Ltd. Tel.: +66 2 721 73 23 sales@stauff.co.th UNITED KINGDOM STAUFF UK Ltd. Tel.: +44 114 251 85 18 sales@stauff.co.uk UNITED STATES STAUFF Corporation Tel.: +1 201 444 78 00 sales@stauffusa.com VIETNAM STAUFF Vietnam Ltd. Tel.: +84 8 3948 10 41 sales@stauff.com.vn Globally available through wholly-owned branches and distributors in all industrial countries. Produktkatalog_PT-RF_EN_04-2015.indd 1 28.04.2015 10:16:13
  • 3. www.stauff.com www.stauff.com Pressure Transmitter § Type PT-RF Product Description The pressure transmitters from the PT-RF series are integrated into fluid technology plants and systems permanently or temporarily using the appropriate process connection adapters. The energy required for a measurement is transferred to the pressure transmitter via the antenna of the reading device using wireless RFID technology. This means that the pressure transmitters require neither internal nor external power supply and are completely maintenance-free. Technical Data Wetted Parts ƒƒ Suitable for liquid and gaseous media Materials ƒƒ Housing: Stainless Steel 1.4305 ƒƒ Sealing (B04): FPM (Viton®) ƒƒ Cap: Polyamide (glass fibre-reinforced) Dimensions / Weight ƒƒ Dimensions: 59 x 26 mm / 2.32 x 1.02 in ƒƒ Weight: 80 g / .18 lbs Temperature Range ƒƒ Media temp.: -40 °C ... +85 °C / -40 °F ... +185 °F ƒƒ Ambient temp.: -40 °C ... +85 °C / -40 °F ... +185 °F ƒƒ Storage temp.: -55 °C ...+125 °C / -67 °F ... +257 °F Electrical Data ƒƒ Sampling rate: typ. 250 ms / max. 400 ms ƒƒ Long-term stability: according to IEC EN 60770-1 max. ± 0,25 % FS* /a ƒƒ Load cycles (106 ): 10 Order Codes PT - RF - B00600 - B04 Reader § Type Reader-PT-RF a Series and Type Pressure Transmitter PT b Version Signal transmission via RFID technology RF c Pressure Range see table d Process Connection G1/4 B04 1/4 NPT N04 Version Pressure Range and Accuracies Pressure Trans- mitter PT-RF Pressure Range (bar /PSI) Type of Measurement Maximum Pressure (bar /PSI) Burst Pressure (bar /PSI) Accuracy (±% FS*) typ. Accuracy (±% FS*) max. B00016 0 ... 16 Relative pressure 32 48 0,25 0,5 0 ... 232 464 696 B00060 0 ... 60 Relative pressure 120 180 0,25 0,5 0 ... 870 1740 2610 B00160 0 ... 160 Relative pressure 320 480 0,25 0,5 0 ... 2320 4641 6961 B00400 0 ... 400 Relative pressure 800 1200 0,25 0,5 0 ... 5801 11603 17405 B00600 0 ... 600 Relative pressure 1200 1800 0,25 0,5 0 ... 8702 17404 26107 Pressure Range and Accuracies * FS = Full Scale Complete system § Type PT-RF-SET Spare Parts / Accessories Product Description The hand-held readers transfer the energy required for a measurement to the pressure transmitter using RFID technology. All that is required is a maximum distance of 1.5 cm / 0.6 in from the antenna to the tip of the pressure transmitter for the duration of the measurement. When the pressure transmitter is activated by the press of a button, a current measured value is determined within only 0.5 seconds and then immediately transmitted back to the reading device together with other relevant information and then output on the illuminated display and stored. Over 15,000 of these measurement sets can be stored in the internal memory of the device. Technical Data Material ƒƒ Housing made of ABS Dimensions / Weight ƒƒ Dimensions: 76 x 35 x 240 mm / 3.0 x 1.38 x 9.45 in ƒƒ Weight: 220 g / .49 lbs Measurements / Display ƒƒ Pressure: in bar and PSI ƒƒ Temperature: in °C and °F ƒƒ Display: graphic, LED backlit ƒƒ Visible area: 55 x 46 mm / 2.17 x 1.81 in ƒƒ Resolution: 128 x 64 Pixel Power Supply ƒƒ Battery: Lithium Ion (3,7 V DC / 900 mAh) ƒƒ Operating time approx. 6h (approx. 1800 individual measurement) Order Code Reader-PT-RF Product Description The PT-RF-SET complete system is compiled in different versions according to customer requirements. All complete systems are supplied in a handy carrying case containing individually shaped foam inserts for a maximum of 10 pressure transmitters and 10 process connection adaptors and offering space for the following components: Standard Option ƒƒ 1x Reader-PT-RF ƒƒ up to 3 Pressure Transmitters PT-RF ƒƒ up to 3 Process Connection Adaptors SDA or SMD ƒƒ 1x Manual and Software on CD ƒƒ 1x Quick Guide ƒƒ 1x USB 2.0 cable(1 m / 3.28 ft) ƒƒ 1x Power Supply incl. country-specific adaptors Order Codes Pressure Transmitter: Pressure Range and Version Pressure Range Version of Pressure Transmitter 000 When ordering a complete system with one or two pressure transmitters, the pressure range for the 2nd and 3rd pressure transmitter is given as “000”. 016 Version pressure transmitter: B00016 (pressure range: 0 ... 16 bar / 0 ... 232 PSI) 060 Version pressure transmitter: B00060 (pressure range: 0 ... 60 bar / 0 ... 870 PSI) 160 Version pressure transmitter: B00160 (pressure range: 0 ... 160 bar / 0 ... 2320 PSI) 400 Version pressure transmitter: B00400 (pressure range: 0 ... 400 bar / 0 ... 5801 PSI) 600 Version pressure transmitter: B00600 (pressure range: 0 ... 600 bar / 0 ... 8702 PSI) e.g. 400 (400 bar) 600 (600 bar) 000 (0 bar) Type of Measurement Start Measurement 1. Switch on the reader using the function button. During the brief start process, the charge state of the lithium ion battery (Battery) is shown on the display and the share of the currently occupied data memory (MemUsed) in percent as well as the current date and time. 2. Position the tip of the antenna of the reader inside the measurement range of the pressure transmitter and hold this position as long as possible during the entire measurement process. a Series and Type Reader Reader-PT-RF Series PT-RF ƒƒ Vibration loading: acc. to IEC 60068-2-6 (20 g) ƒƒ Shock loading: acc. to IEC 60068-2-27 (30 g) 11ms PC Software The software included with the delivery allows transmission of the stored measured values from the reading device to the PC, subsequent evaluation and export, e.g. to Microsoft Excel®. Temperature Range: ƒƒ Ambient temp.: -20 °C ... +70 °C / -4 °F ... +158 °F ƒƒ Storage temp.: -25 °C ... +60 °C / -13 °F ... +140 °F ƒƒ CE certified Electrical Data / Interface ƒƒ Sampling rate: typ. 250 ms / max. 400 ms ƒƒ Interface: Micro USB ƒƒ EMV: EN 61326-1:2013 EN 300330 Protection Rating ƒƒ IP65 protection rating: Dust tight and protected against water jets Dimensional drawing: All dimensions in mm (in). PT-RF - SET - 2 - 400 / 600 / 000 - B g Series PT-RF d Pressure Range / Version 1st pressure transmitter see table e Pressure Range / Version 2nd Pressure Transmitter see table f Pressure Range / Version 3rd Pressure Transmitter see table g Process Connection Adaptor Adaptor SDA for process connection G1/4 (B04) B Adaptor SMD for process connection 1/4NPT (N04) N a Series and Type Series PT-RF PT-RF b Version Complete system in case SET c Number of Pressure Transmitters in the Set 1x pressure transmitter 1 2x pressure transmitter 2 3x pressure transmitter 3 G1/4 Ø18,9 (.74) Ø24 (.94) 8,7 (.34)47 (1.85) 12 (.47) SW24 (Hex.94) Process connection G1/4 (B04) Process connection 1/4NPT (N04) Process Connection Adaptors for Pressure Transmitter PT-RF Various adaptors are available in addition to the pressure transmitters from the PT-RF series, allowing connection to the known STAUFF Test 20 system as well as installation in pipes. SMD20-1/4NPT-C6F Adaptor for process connection 1/4NPT (N04) on test coupling STAUFF Test 20 (connection thread M16 x 2) SRS-G1/4-***-VG-C6F Straight fitting with adaptor Note: Please replace *** with tube-Ø and series (L or S). SDA20-G1/4-C6F Adaptor for process connection G1/4 (B04) on test coupling STAUFF Test 20 (connection thread M16 x 2) Standard option: ƒƒ Reader-PT-RF ƒƒ Manual and software on CD ƒƒ Quick guide ƒƒ USB 2.0 cable (1 m / 3.28 ft) ƒƒ 5 V DC / 1 A power supply incl. country-specific adaptors Individual Measurement (Single Value) 3. Start the individual measurement by tapping the function button once. Permanent Measurement (Multiple Values) 3. Start the permanent measurement by holding down the function button. The simplest way of recognising the successful start of a permanent measurement is the change in the corresponding symbol in the upper right-hand corner of the display. The absolute number of the values determined as part of the measurement process is shown below the current pressure. 4. End a continuous measurement by releasing the function key. Display after successful individual measurement Display after successful permanent measurement 1 Serial number 2 Upper full scale 3 Type of measurement 4 Current pressure 5 Measurement ID 6 Current temperature 1 Serial number 2 Upper full scale 3 Type of measurement 4 Last pressure 5 Ø pressure 6 Number of measurements 7 Measurement ID 8 Ø temperature I MIN /MAX pressure 1 2 3 4 5 1 32 4 7 8 6 5 Reader-PT-RF Set Up Connection Reader Buttons Display Measurement Range Distance: max. 1.5 cm / 0.6 in within the measurement range indicated Antenna Cap Housing SW24 Hex .95 Pressure Transmitter (direct assembly without adapter) Application Side Order Codes Spare Parts / Accessories a Spare Parts / Accessories Case, small Case-Reader-PT-RF Case, large Case-PT-RF-SET 5 V DC / 1 A power supply incl. country-specific Charger-Set-Reader-PT-RF adaptors and USB 2.0 cable Adaptor for pressure transmitter (B04) SDA20-G1/4-C6F Adaptor for pressure transmitter (N04) SMD20-1/4NPT-C6F Straight fitting with adaptor SRS-G1/4-***-VG-C6F Product Description In addition to the Charger-Set-Reader-PT-RF which is available as a spare part, the Case-PT-RF-Set is also available as an individual item for assembling a complete system later on. The Case-Reader-PT-RF is available if only a storage case for the reading device is required. It only provides space for the reading device and the associated accessories (without pressure transmitters and process connection adaptors). Protection Rating ƒƒ IP67 protection rating: Dust tight and protected against splashing water 6 1/4NPT Temperature behaviour: max. ± 0,2 % FS* /10K (test condition 25 °C; 45 % v. F.) I Complete system in case PT-RF-SET fedcba a adcba Case-Reader-PT-RF Produktkatalog_PT-RF_EN_04-2015.indd 2 28.04.2015 10:16:31
  • 4. www.stauff.com www.stauff.com Pressure Transmitter § Type PT-RF Product Description The pressure transmitters from the PT-RF series are integrated into fluid technology plants and systems permanently or temporarily using the appropriate process connection adapters. The energy required for a measurement is transferred to the pressure transmitter via the antenna of the reading device using wireless RFID technology. This means that the pressure transmitters require neither internal nor external power supply and are completely maintenance-free. Technical Data Wetted Parts ƒƒ Suitable for liquid and gaseous media Materials ƒƒ Housing: Stainless Steel 1.4305 ƒƒ Sealing (B04): FPM (Viton®) ƒƒ Cap: Polyamide (glass fibre-reinforced) Dimensions / Weight ƒƒ Dimensions: 59 x 26 mm / 2.32 x 1.02 in ƒƒ Weight: 80 g / .18 lbs Temperature Range ƒƒ Media temp.: -40 °C ... +85 °C / -40 °F ... +185 °F ƒƒ Ambient temp.: -40 °C ... +85 °C / -40 °F ... +185 °F ƒƒ Storage temp.: -55 °C ...+125 °C / -67 °F ... +257 °F Electrical Data ƒƒ Sampling rate: typ. 250 ms / max. 400 ms ƒƒ Long-term stability: according to IEC EN 60770-1 max. ± 0,25 % FS* /a ƒƒ Load cycles (106 ): 10 Order Codes PT - RF - B00600 - B04 Reader § Type Reader-PT-RF a Series and Type Pressure Transmitter PT b Version Signal transmission via RFID technology RF c Pressure Range see table d Process Connection G1/4 B04 1/4 NPT N04 Version Pressure Range and Accuracies Pressure Trans- mitter PT-RF Pressure Range (bar /PSI) Type of Measurement Maximum Pressure (bar /PSI) Burst Pressure (bar /PSI) Accuracy (±% FS*) typ. Accuracy (±% FS*) max. B00016 0 ... 16 Relative pressure 32 48 0,25 0,5 0 ... 232 464 696 B00060 0 ... 60 Relative pressure 120 180 0,25 0,5 0 ... 870 1740 2610 B00160 0 ... 160 Relative pressure 320 480 0,25 0,5 0 ... 2320 4641 6961 B00400 0 ... 400 Relative pressure 800 1200 0,25 0,5 0 ... 5801 11603 17405 B00600 0 ... 600 Relative pressure 1200 1800 0,25 0,5 0 ... 8702 17404 26107 Pressure Range and Accuracies * FS = Full Scale Complete system § Type PT-RF-SET Spare Parts / Accessories Product Description The hand-held readers transfer the energy required for a measurement to the pressure transmitter using RFID technology. All that is required is a maximum distance of 1.5 cm / 0.6 in from the antenna to the tip of the pressure transmitter for the duration of the measurement. When the pressure transmitter is activated by the press of a button, a current measured value is determined within only 0.5 seconds and then immediately transmitted back to the reading device together with other relevant information and then output on the illuminated display and stored. Over 15,000 of these measurement sets can be stored in the internal memory of the device. Technical Data Material ƒƒ Housing made of ABS Dimensions / Weight ƒƒ Dimensions: 76 x 35 x 240 mm / 3.0 x 1.38 x 9.45 in ƒƒ Weight: 220 g / .49 lbs Measurements / Display ƒƒ Pressure: in bar and PSI ƒƒ Temperature: in °C and °F ƒƒ Display: graphic, LED backlit ƒƒ Visible area: 55 x 46 mm / 2.17 x 1.81 in ƒƒ Resolution: 128 x 64 Pixel Power Supply ƒƒ Battery: Lithium Ion (3,7 V DC / 900 mAh) ƒƒ Operating time approx. 6h (approx. 1800 individual measurement) Order Code Reader-PT-RF Product Description The PT-RF-SET complete system is compiled in different versions according to customer requirements. All complete systems are supplied in a handy carrying case containing individually shaped foam inserts for a maximum of 10 pressure transmitters and 10 process connection adaptors and offering space for the following components: Standard Option ƒƒ 1x Reader-PT-RF ƒƒ up to 3 Pressure Transmitters PT-RF ƒƒ up to 3 Process Connection Adaptors SDA or SMD ƒƒ 1x Manual and Software on CD ƒƒ 1x Quick Guide ƒƒ 1x USB 2.0 cable(1 m / 3.28 ft) ƒƒ 1x Power Supply incl. country-specific adaptors Order Codes Pressure Transmitter: Pressure Range and Version Pressure Range Version of Pressure Transmitter 000 When ordering a complete system with one or two pressure transmitters, the pressure range for the 2nd and 3rd pressure transmitter is given as “000”. 016 Version pressure transmitter: B00016 (pressure range: 0 ... 16 bar / 0 ... 232 PSI) 060 Version pressure transmitter: B00060 (pressure range: 0 ... 60 bar / 0 ... 870 PSI) 160 Version pressure transmitter: B00160 (pressure range: 0 ... 160 bar / 0 ... 2320 PSI) 400 Version pressure transmitter: B00400 (pressure range: 0 ... 400 bar / 0 ... 5801 PSI) 600 Version pressure transmitter: B00600 (pressure range: 0 ... 600 bar / 0 ... 8702 PSI) e.g. 400 (400 bar) 600 (600 bar) 000 (0 bar) Type of Measurement Start Measurement 1. Switch on the reader using the function button. During the brief start process, the charge state of the lithium ion battery (Battery) is shown on the display and the share of the currently occupied data memory (MemUsed) in percent as well as the current date and time. 2. Position the tip of the antenna of the reader inside the measurement range of the pressure transmitter and hold this position as long as possible during the entire measurement process. a Series and Type Reader Reader-PT-RF Series PT-RF ƒƒ Vibration loading: acc. to IEC 60068-2-6 (20 g) ƒƒ Shock loading: acc. to IEC 60068-2-27 (30 g) 11ms PC Software The software included with the delivery allows transmission of the stored measured values from the reading device to the PC, subsequent evaluation and export, e.g. to Microsoft Excel®. Temperature Range: ƒƒ Ambient temp.: -20 °C ... +70 °C / -4 °F ... +158 °F ƒƒ Storage temp.: -25 °C ... +60 °C / -13 °F ... +140 °F ƒƒ CE certified Electrical Data / Interface ƒƒ Sampling rate: typ. 250 ms / max. 400 ms ƒƒ Interface: Micro USB ƒƒ EMV: EN 61326-1:2013 EN 300330 Protection Rating ƒƒ IP65 protection rating: Dust tight and protected against water jets Dimensional drawing: All dimensions in mm (in). PT-RF - SET - 2 - 400 / 600 / 000 - B g Series PT-RF d Pressure Range / Version 1st pressure transmitter see table e Pressure Range / Version 2nd Pressure Transmitter see table f Pressure Range / Version 3rd Pressure Transmitter see table g Process Connection Adaptor Adaptor SDA for process connection G1/4 (B04) B Adaptor SMD for process connection 1/4NPT (N04) N a Series and Type Series PT-RF PT-RF b Version Complete system in case SET c Number of Pressure Transmitters in the Set 1x pressure transmitter 1 2x pressure transmitter 2 3x pressure transmitter 3 G1/4 Ø18,9 (.74) Ø24 (.94) 8,7 (.34)47 (1.85) 12 (.47) SW24 (Hex.94) Process connection G1/4 (B04) Process connection 1/4NPT (N04) Process Connection Adaptors for Pressure Transmitter PT-RF Various adaptors are available in addition to the pressure transmitters from the PT-RF series, allowing connection to the known STAUFF Test 20 system as well as installation in pipes. SMD20-1/4NPT-C6F Adaptor for process connection 1/4NPT (N04) on test coupling STAUFF Test 20 (connection thread M16 x 2) SRS-G1/4-***-VG-C6F Straight fitting with adaptor Note: Please replace *** with tube-Ø and series (L or S). SDA20-G1/4-C6F Adaptor for process connection G1/4 (B04) on test coupling STAUFF Test 20 (connection thread M16 x 2) Standard option: ƒƒ Reader-PT-RF ƒƒ Manual and software on CD ƒƒ Quick guide ƒƒ USB 2.0 cable (1 m / 3.28 ft) ƒƒ 5 V DC / 1 A power supply incl. country-specific adaptors Individual Measurement (Single Value) 3. Start the individual measurement by tapping the function button once. Permanent Measurement (Multiple Values) 3. Start the permanent measurement by holding down the function button. The simplest way of recognising the successful start of a permanent measurement is the change in the corresponding symbol in the upper right-hand corner of the display. The absolute number of the values determined as part of the measurement process is shown below the current pressure. 4. End a continuous measurement by releasing the function key. Display after successful individual measurement Display after successful permanent measurement 1 Serial number 2 Upper full scale 3 Type of measurement 4 Current pressure 5 Measurement ID 6 Current temperature 1 Serial number 2 Upper full scale 3 Type of measurement 4 Last pressure 5 Ø pressure 6 Number of measurements 7 Measurement ID 8 Ø temperature I MIN /MAX pressure 1 2 3 4 5 1 32 4 7 8 6 5 Reader-PT-RF Set Up Connection Reader Buttons Display Measurement Range Distance: max. 1.5 cm / 0.6 in within the measurement range indicated Antenna Cap Housing SW24 Hex .95 Pressure Transmitter (direct assembly without adapter) Application Side Order Codes Spare Parts / Accessories a Spare Parts / Accessories Case, small Case-Reader-PT-RF Case, large Case-PT-RF-SET 5 V DC / 1 A power supply incl. country-specific Charger-Set-Reader-PT-RF adaptors and USB 2.0 cable Adaptor for pressure transmitter (B04) SDA20-G1/4-C6F Adaptor for pressure transmitter (N04) SMD20-1/4NPT-C6F Straight fitting with adaptor SRS-G1/4-***-VG-C6F Product Description In addition to the Charger-Set-Reader-PT-RF which is available as a spare part, the Case-PT-RF-Set is also available as an individual item for assembling a complete system later on. The Case-Reader-PT-RF is available if only a storage case for the reading device is required. It only provides space for the reading device and the associated accessories (without pressure transmitters and process connection adaptors). Protection Rating ƒƒ IP67 protection rating: Dust tight and protected against splashing water 6 1/4NPT Temperature behaviour: max. ± 0,2 % FS* /10K (test condition 25 °C; 45 % v. F.) I Complete system in case PT-RF-SET fedcba a adcba Case-Reader-PT-RF Produktkatalog_PT-RF_EN_04-2015.indd 2 28.04.2015 10:16:31
  • 5. www.stauff.com www.stauff.com Pressure Transmitter § Type PT-RF Product Description The pressure transmitters from the PT-RF series are integrated into fluid technology plants and systems permanently or temporarily using the appropriate process connection adapters. The energy required for a measurement is transferred to the pressure transmitter via the antenna of the reading device using wireless RFID technology. This means that the pressure transmitters require neither internal nor external power supply and are completely maintenance-free. Technical Data Wetted Parts ƒƒ Suitable for liquid and gaseous media Materials ƒƒ Housing: Stainless Steel 1.4305 ƒƒ Sealing (B04): FPM (Viton®) ƒƒ Cap: Polyamide (glass fibre-reinforced) Dimensions / Weight ƒƒ Dimensions: 59 x 26 mm / 2.32 x 1.02 in ƒƒ Weight: 80 g / .18 lbs Temperature Range ƒƒ Media temp.: -40 °C ... +85 °C / -40 °F ... +185 °F ƒƒ Ambient temp.: -40 °C ... +85 °C / -40 °F ... +185 °F ƒƒ Storage temp.: -55 °C ...+125 °C / -67 °F ... +257 °F Electrical Data ƒƒ Sampling rate: typ. 250 ms / max. 400 ms ƒƒ Long-term stability: according to IEC EN 60770-1 max. ± 0,25 % FS* /a ƒƒ Load cycles (106 ): 10 Order Codes PT - RF - B00600 - B04 Reader § Type Reader-PT-RF a Series and Type Pressure Transmitter PT b Version Signal transmission via RFID technology RF c Pressure Range see table d Process Connection G1/4 B04 1/4 NPT N04 Version Pressure Range and Accuracies Pressure Trans- mitter PT-RF Pressure Range (bar /PSI) Type of Measurement Maximum Pressure (bar /PSI) Burst Pressure (bar /PSI) Accuracy (±% FS*) typ. Accuracy (±% FS*) max. B00016 0 ... 16 Relative pressure 32 48 0,25 0,5 0 ... 232 464 696 B00060 0 ... 60 Relative pressure 120 180 0,25 0,5 0 ... 870 1740 2610 B00160 0 ... 160 Relative pressure 320 480 0,25 0,5 0 ... 2320 4641 6961 B00400 0 ... 400 Relative pressure 800 1200 0,25 0,5 0 ... 5801 11603 17405 B00600 0 ... 600 Relative pressure 1200 1800 0,25 0,5 0 ... 8702 17404 26107 Pressure Range and Accuracies * FS = Full Scale Complete system § Type PT-RF-SET Spare Parts / Accessories Product Description The hand-held readers transfer the energy required for a measurement to the pressure transmitter using RFID technology. All that is required is a maximum distance of 1.5 cm / 0.6 in from the antenna to the tip of the pressure transmitter for the duration of the measurement. When the pressure transmitter is activated by the press of a button, a current measured value is determined within only 0.5 seconds and then immediately transmitted back to the reading device together with other relevant information and then output on the illuminated display and stored. Over 15,000 of these measurement sets can be stored in the internal memory of the device. Technical Data Material ƒƒ Housing made of ABS Dimensions / Weight ƒƒ Dimensions: 76 x 35 x 240 mm / 3.0 x 1.38 x 9.45 in ƒƒ Weight: 220 g / .49 lbs Measurements / Display ƒƒ Pressure: in bar and PSI ƒƒ Temperature: in °C and °F ƒƒ Display: graphic, LED backlit ƒƒ Visible area: 55 x 46 mm / 2.17 x 1.81 in ƒƒ Resolution: 128 x 64 Pixel Power Supply ƒƒ Battery: Lithium Ion (3,7 V DC / 900 mAh) ƒƒ Operating time approx. 6h (approx. 1800 individual measurement) Order Code Reader-PT-RF Product Description The PT-RF-SET complete system is compiled in different versions according to customer requirements. All complete systems are supplied in a handy carrying case containing individually shaped foam inserts for a maximum of 10 pressure transmitters and 10 process connection adaptors and offering space for the following components: Standard Option ƒƒ 1x Reader-PT-RF ƒƒ up to 3 Pressure Transmitters PT-RF ƒƒ up to 3 Process Connection Adaptors SDA or SMD ƒƒ 1x Manual and Software on CD ƒƒ 1x Quick Guide ƒƒ 1x USB 2.0 cable(1 m / 3.28 ft) ƒƒ 1x Power Supply incl. country-specific adaptors Order Codes Pressure Transmitter: Pressure Range and Version Pressure Range Version of Pressure Transmitter 000 When ordering a complete system with one or two pressure transmitters, the pressure range for the 2nd and 3rd pressure transmitter is given as “000”. 016 Version pressure transmitter: B00016 (pressure range: 0 ... 16 bar / 0 ... 232 PSI) 060 Version pressure transmitter: B00060 (pressure range: 0 ... 60 bar / 0 ... 870 PSI) 160 Version pressure transmitter: B00160 (pressure range: 0 ... 160 bar / 0 ... 2320 PSI) 400 Version pressure transmitter: B00400 (pressure range: 0 ... 400 bar / 0 ... 5801 PSI) 600 Version pressure transmitter: B00600 (pressure range: 0 ... 600 bar / 0 ... 8702 PSI) e.g. 400 (400 bar) 600 (600 bar) 000 (0 bar) Type of Measurement Start Measurement 1. Switch on the reader using the function button. During the brief start process, the charge state of the lithium ion battery (Battery) is shown on the display and the share of the currently occupied data memory (MemUsed) in percent as well as the current date and time. 2. Position the tip of the antenna of the reader inside the measurement range of the pressure transmitter and hold this position as long as possible during the entire measurement process. a Series and Type Reader Reader-PT-RF Series PT-RF ƒƒ Vibration loading: acc. to IEC 60068-2-6 (20 g) ƒƒ Shock loading: acc. to IEC 60068-2-27 (30 g) 11ms PC Software The software included with the delivery allows transmission of the stored measured values from the reading device to the PC, subsequent evaluation and export, e.g. to Microsoft Excel®. Temperature Range: ƒƒ Ambient temp.: -20 °C ... +70 °C / -4 °F ... +158 °F ƒƒ Storage temp.: -25 °C ... +60 °C / -13 °F ... +140 °F ƒƒ CE certified Electrical Data / Interface ƒƒ Sampling rate: typ. 250 ms / max. 400 ms ƒƒ Interface: Micro USB ƒƒ EMV: EN 61326-1:2013 EN 300330 Protection Rating ƒƒ IP65 protection rating: Dust tight and protected against water jets Dimensional drawing: All dimensions in mm (in). PT-RF - SET - 2 - 400 / 600 / 000 - B g Series PT-RF d Pressure Range / Version 1st pressure transmitter see table e Pressure Range / Version 2nd Pressure Transmitter see table f Pressure Range / Version 3rd Pressure Transmitter see table g Process Connection Adaptor Adaptor SDA for process connection G1/4 (B04) B Adaptor SMD for process connection 1/4NPT (N04) N a Series and Type Series PT-RF PT-RF b Version Complete system in case SET c Number of Pressure Transmitters in the Set 1x pressure transmitter 1 2x pressure transmitter 2 3x pressure transmitter 3 G1/4 Ø18,9 (.74) Ø24 (.94) 8,7 (.34)47 (1.85) 12 (.47) SW24 (Hex.94) Process connection G1/4 (B04) Process connection 1/4NPT (N04) Process Connection Adaptors for Pressure Transmitter PT-RF Various adaptors are available in addition to the pressure transmitters from the PT-RF series, allowing connection to the known STAUFF Test 20 system as well as installation in pipes. SMD20-1/4NPT-C6F Adaptor for process connection 1/4NPT (N04) on test coupling STAUFF Test 20 (connection thread M16 x 2) SRS-G1/4-***-VG-C6F Straight fitting with adaptor Note: Please replace *** with tube-Ø and series (L or S). SDA20-G1/4-C6F Adaptor for process connection G1/4 (B04) on test coupling STAUFF Test 20 (connection thread M16 x 2) Standard option: ƒƒ Reader-PT-RF ƒƒ Manual and software on CD ƒƒ Quick guide ƒƒ USB 2.0 cable (1 m / 3.28 ft) ƒƒ 5 V DC / 1 A power supply incl. country-specific adaptors Individual Measurement (Single Value) 3. Start the individual measurement by tapping the function button once. Permanent Measurement (Multiple Values) 3. Start the permanent measurement by holding down the function button. The simplest way of recognising the successful start of a permanent measurement is the change in the corresponding symbol in the upper right-hand corner of the display. The absolute number of the values determined as part of the measurement process is shown below the current pressure. 4. End a continuous measurement by releasing the function key. Display after successful individual measurement Display after successful permanent measurement 1 Serial number 2 Upper full scale 3 Type of measurement 4 Current pressure 5 Measurement ID 6 Current temperature 1 Serial number 2 Upper full scale 3 Type of measurement 4 Last pressure 5 Ø pressure 6 Number of measurements 7 Measurement ID 8 Ø temperature I MIN /MAX pressure 1 2 3 4 5 1 32 4 7 8 6 5 Reader-PT-RF Set Up Connection Reader Buttons Display Measurement Range Distance: max. 1.5 cm / 0.6 in within the measurement range indicated Antenna Cap Housing SW24 Hex .95 Pressure Transmitter (direct assembly without adapter) Application Side Order Codes Spare Parts / Accessories a Spare Parts / Accessories Case, small Case-Reader-PT-RF Case, large Case-PT-RF-SET 5 V DC / 1 A power supply incl. country-specific Charger-Set-Reader-PT-RF adaptors and USB 2.0 cable Adaptor for pressure transmitter (B04) SDA20-G1/4-C6F Adaptor for pressure transmitter (N04) SMD20-1/4NPT-C6F Straight fitting with adaptor SRS-G1/4-***-VG-C6F Product Description In addition to the Charger-Set-Reader-PT-RF which is available as a spare part, the Case-PT-RF-Set is also available as an individual item for assembling a complete system later on. The Case-Reader-PT-RF is available if only a storage case for the reading device is required. It only provides space for the reading device and the associated accessories (without pressure transmitters and process connection adaptors). Protection Rating ƒƒ IP67 protection rating: Dust tight and protected against splashing water 6 1/4NPT Temperature behaviour: max. ± 0,2 % FS* /10K (test condition 25 °C; 45 % v. F.) I Complete system in case PT-RF-SET fedcba a adcba Case-Reader-PT-RF Produktkatalog_PT-RF_EN_04-2015.indd 2 28.04.2015 10:16:31
  • 6. Local Solutions For Individual Customers Worldwide Product Catalogue Pressure Transmitter and Reader of the PT-RF Series Local Solutions For Individual Customers Worldwide Product Catalogue PT-RF § English § 9910000263 § 04/2015 www.facebook.com/stauffgroup www.twitter.com/stauffgroup www.youtube.com/stauffgroup www.stauff.com Series PT-RF Pressure Transmitter and Reader of the Series PT-RF The PT-RF series of pressure transmitters are an alternative solution for universal pressure measurements for fluid technology applications, which will provide benefits for system operators, maintenance personnel and repair technicians as well as for original equipment manufacturers. The advantages resulting from the use of the new technology for system operators, maintenance personnel and repair technicians are clear: Measurements can be carried very easily, without extensive training and within a few seconds at the press of a button and then documented in a reliable process. Unscrewing and re-installing pressure gauges or other measuring and display devices – practically a temporary opening of the system – is not required. Potential hazards for people, machines and the environment, for example from emitted residual oil in the test hose or leaks at the measuring point, as well as ingress of dirt into the system (e.g. in dusty environments) can be effectively excluded. Original equipment manufacturers will also benefit from this new technology: If the pressure transmitters are installed at their factory already, the innovative technology can provide a competitive edge over alternative suppliers and open up specific advantages for the users, increasing the value retention of their own devices in the long term. If the pressure transmitters are installed directly in the system or pipeline for permanent use, they protrude only slightly more than conventional hydraulic test couplings and meet the highest demands with regard to space requirements and weight. www.stauff.com Originating and located in Werdohl in the German Sauerland region, we have become an internationally leading developer, manufacturer and supplier of pipework equipment and hydraulic components under the brand name STAUFF. The STAUFF product range includes: § STAUFF Clamps § STAUFF Test § Filtration Technology § Diagtronics § Hydraulic Accessories § Valves § Fluid Connectors Decades of experience, highly-motivated and qualified staff, state-of-the-art manufacturing technologies and a foresighted management give us the reputation of being a competitive partner. Our in-house laboratories carry out constant tests in line with international standards on all products. Certified in accordance with ISO 9001:2008 (Quality), ISO 14001:2004 (Environmental Protection) and OHSAS 18001:2007 (Occupational Health and Safety), our management system continually strives for perfection. Many of our products have been successfully tested and approved by several international organisations and institutes. Our well-stocked warehouses and flexible production lines ensure prompt reactions and short delivery times. Represented by a tight network of distributors and wholly- owned manufacturing facilities, distribution bases and warehouses in 18 countries worldwide, we are close to you. Our subsidiaries also supply additional retail products related to the fluid power industry, thereby offering a near-complete range of industry-specific key products. Local Solutions For Individual Customers Worldwide. GERMANY Walter Stauffenberg GmbH Co. KG Im Ehrenfeld 4 58791 Werdohl Tel.: +49 23 92 916 0 Fax: +49 23 92 916 160 sales@stauff.com AUSTRALIA STAUFF Corporation Pty Ltd Tel.: +61 2 4271 9000 sales@stauff.com.au BRAZIL STAUFF Brasil Ltda. Tel.: +55 11 47 72 72 00 stauff@stauffbrasil.com CANADA STAUFF Canada Ltd. Tel.: +1 416 282 46 08 sales@stauffcanada.com CHINA STAUFF China Tel.: +86 21 68 18 70 00 info@stauff.com.cn FRANCE STAUFF S.A.S. Tel.: +33 2 54 50 55 50 direction@stauffsa.com INDIA STAUFF India Pvt. Ltd. Tel.: +91 20 66 20 24 66 sales@stauffindia.com IRELAND STAUFF Ireland Tel.: +44 28 92 60 69 00 sales@stauffireland.com ITALY STAUFF Italia S.r.l. Tel.: +39 031 65 84 94 sales@stauff.it KOREA STAUFF Korea Ltd. Tel.: +82 51 266 66 66 info@stauff.co.kr MALAYSIA STAUFF South East Asia Sdn Bhd Tel.: +60 3 5637 78 88 sales@stauff.com.my NEW ZEALAND STAUFF Corporation (NZ) Ltd. Tel.: +64 9 271 48 12 info@stauff.co.nz POLAND STAUFF Polska Sp. z o.o. Tel.: +48 58 660 11 60 sales@stauff.pl RUSSIAN FEDERATION STAUFF LLC Tel.: +7 495 276 16 50 sales@stauff.ru THAILAND STAUFF (Thailand) Co., Ltd. Tel.: +66 2 721 73 23 sales@stauff.co.th UNITED KINGDOM STAUFF UK Ltd. Tel.: +44 114 251 85 18 sales@stauff.co.uk UNITED STATES STAUFF Corporation Tel.: +1 201 444 78 00 sales@stauffusa.com VIETNAM STAUFF Vietnam Ltd. Tel.: +84 8 3948 10 41 sales@stauff.com.vn Globally available through wholly-owned branches and distributors in all industrial countries. Produktkatalog_PT-RF_EN_04-2015.indd 1 28.04.2015 10:16:13

Related Documents